FIRE ALARM SYSTEM – CONVENTIONAL

A conventional system employs one or more initiating circuits, connected to sensors (initiating devices) wired in parallel. These sensors are devised to decrease the circuits resistance when the environmental influence on any sensor exceeds a predetermined threshold. In a conventional system the information density is limited to the number of such circuits used. At times, a floor plan of the building is often placed near the main entrance with the defined zones drawn up, and LEDs indicating whether a particular circuit/zone has been activated. Another common method is to have the different zones listed in a column, with an LED to the left of each zone name.

FIRE ALARM CONTROL PANELS

Conventional fire alarm system is cost-effective and adaptable to a variety of applications, big or small … making it one of the most flexible products on the market.

MANUAL CALL POINTS – MS/ABS TYPES

This device is provided to enable manual operation of the fire alarm system ie Where you discover fire/smoke and the fire alarm is not sounding.

All visible surfaces (except for the frangible elements) of the Manual Call Point shall be red.

They are usually located in corridors and at the Fire Indicator Panel.

HOOTER – MS/ABS TYPES

Hooters / Sounders are very important part of the Fire Detection & Alarm system. It will alert the people and help to take necessary steps to stop the Fire.

RESPONSE INDICATORS

Response Indicators commonly named as “RI” is remote indicator for smoke detectors. It is used commonly for the detectors installed closed rooms / cabins, above False ceiling.

RI gets activate and glow steady red LED, when the detector connected with RI get activate. Activation of RI is associated with the smoke detector and provide only visual indication.

FIRE BUS

  • Inbuilt MCB & Hooter with single zone Fire alarm Panel.
  • Battery Charger & Battery backup facility.
  • Best suited for shops, showrooms, houses, temporary locations & schools.
  • Small size, light weight, cylindrical shape.
  • Compatible with up to 8 smoke detector(any make)
  • System off, system normal, system silence facility.
  • System healthy, fire,A.C.fail indications.
  • External Hooter & M.C.B connectivity Facility.
  • Inbuilt hooter with/without strobe optional.

WIRELESS FIRE ALARM SYSTEMS

NO wiring and conducting works on radio waves

Each detector works as a independently unit. So in case of non working of particular detector it does not have any effect on the system.

Zero maintenance and no AMC required.
Immediate Installations. 200 no. of detectors with panel can be installed in a single day even when building is occupied.

Can be installed in running office complex / factory etc.

Complete flexibility. Any time there is a requirement for any modernization of the building. Any detector / panel can be shifted as per requirements.

 

IMAGES

 

FIRE ALARM PANEL